Record laboratory panels and verify the final report

Keep sample details, analytes, units, reference ranges, source documents, and reviewed results together.

18 minSource reviewed November 23, 2026Revision 2

Reviewed against current application source. Screenshots use fictional local training data.

Understand the workflow

#

Laboratory appointments show Lab Results inside the current Technician chart. A panel groups the sample and method with its analytes, results, units, ranges, flags, and notes. Use a linked laboratory appointment when the testing belongs to another clinical case so the team can follow the relationship through discharge and billing.

Document extraction helps enter data; it does not verify the laboratory result. Imported names, decimal marks, units, reference ranges, and flags require comparison with the original report. AI evaluation, when enabled, is a separate review aid. The responsible clinician must review the saved data and interpretation before a report is printed or shared.

Before you start

#
  • Confirm the customer, pet, date, and Laboratory appointment type. Obtain the original result document and confirm which sample and order belong to the patient.
  • For testing linked to a consultation, surgery, or stay, check the parent relationship and where charges belong. Ensure that you have permission to edit an unfinished clinical record.
  • Document extraction appears only when account AI is enabled and the laboratory extraction feature is available. Manual panel entry remains available.

Do it in Übik

#
  1. Open the Laboratory appointment in Technician and use Lab Results. Add a panel and enter a useful Panel name, Sample type, Method, and Order number where available.
  2. Add or review the analyte rows. Confirm each result, unit, reference range, flag, and note against the source. Keep distinct sample or result groups in separate panels when appropriate.
  3. If using Extract from document, select the correct photo or PDF. Include column headings in the first crop. For a headerless continuation of the same table on the same page, use Add continuation and review the numbered selections.
  4. Finish extraction and inspect every returned row in the editable panel. Correct unreadable or missing information manually; do not accept a plausible-looking value without source evidence.
  5. Attach the original report in Documents. Review the saved panel and any clinician evaluation. When AI evaluation is available, review its output separately before accepting it into the record.
  6. Use the laboratory print or sharing actions only after review. Reception should check patient identity, the saved report, linked charges, and the intended owner handoff before checkout.
Record laboratory panels and verify the final report — actual Übik screen
Actual Übik screen with fictional training data, cropped to the controls used in this lesson. Enlarge screenshot

Try a fictional case

#

Fictional patient Coco has a two-page external laboratory report. Page one includes the table headings and two analyte blocks. The employee selects the first block with headings, adds the continuation on that page, and treats the next page as its own table context.

The extracted panel includes an analyte unit that needs correction. The employee compares it with the original, fixes the unit and associated result context, and asks the clinician to review before sharing. The exercise concerns transcription accuracy, not interpretation of a real medical result.

Record laboratory panels and verify the final report — actual Übik screen
Actual Übik screen with fictional training data, cropped to the controls used in this lesson. Enlarge screenshot

Avoid common mistakes

#
  • Confusing a sample label with a reviewed laboratory report can send incomplete information to the owner. Check the actual document preview.
  • A reference range from another species, sample, or incompatible unit can mislead. Confirm the range context; an administrator can review account analyte aliases when a known name does not match.
  • Using extraction output or an AI evaluation without review can preserve a transcription error in the final report.

Troubleshoot the result

#
  • If Lab Results is absent, verify the appointment type and current portal. The deprecated Lab Edit page is not the primary lesson workflow.
  • If extraction misses a second block, check the saved crop previews and continuation selection before starting another import. Compare the existing rows to avoid duplicates.
  • If a saved panel or printed report still differs from the source after correction, report the affected analyte, unit, source page, and appointment type through Help without replacing the entire history.

Check your understanding

#
A second table block on the same page has no headings. How should you extract it?

Complete the lesson

#

Saved only in this browser. This is a personal practice checklist, not a clinic training record.

Related guides